UBT-140K-FPA Battery Energy Storage Cabinet

UBT-140K-FPA combines 140.67 kWh of nominal battery energy with 60 kW rated off-grid output in a cabinet-format system. LiFePO₄ cells, air cooling and front-access controls provide a defined starting point for commercial and industrial storage projects.

OEM & ODM Services Available
140.67kWhNominal battery energy
60kWRated off-grid output

DESIGN & SELECTION

Energy and power for your operating plan.

01

140.67 kWh for project energy planning

Assess energy demand alongside 60 kW rated off-grid output. Comparing both figures helps define priority loads and the required operating schedule.

02

A serviceable cabinet layout

Front controls, door access and ventilation openings bring operating and service areas together. Plan clearance and airflow around the air-cooled cabinet.

03

Select for the site operating mode

Define whether the project requires grid interaction, selected-load backup or scheduled charging. HSY can discuss the required controls and system scope against the site electrical conditions.

LOOK CLOSER

Inspect the cabinet design.

UBT-140K-FPA — Cabinet angled view — OEM branding illustration
Cabinet angled view — OEM branding illustration
UBT-140K-FPA — Front control area
Front control area
UBT-140K-FPA — Door and ventilation detail
Door and ventilation detail

SYSTEM CONFIGURATION

Plan a coordinated equipment package.

The cabinet configuration uses LiFePO₄ cells in a 1P20S × 7 arrangement, with air cooling and aerosol fire protection. The project equipment schedule identifies the PCS, BMS, EMS functions and protection equipment. Optional solar-input equipment and installation services are listed separately.

Technical specifications

ModelUBT-140K-FPA
Nominal battery energy140.67 kWh
System operating voltage range392–504 V DC
Battery chemistryLiFePO₄
Cell capacity314 Ah
Cell configuration1P20S × 7
Rated off-grid output60 kW
Maximum grid-side input (load + charging)90 kW
AC voltage400 / 230 V AC
AC frequency50 / 60 Hz
Maximum off-grid output current96 A
Maximum grid-side input current130 A
Rated charge / discharge rate0.4 C
Communication interfacesEthernet / Wi-Fi / 4G
Enclosure protection ratingIP54
Charge temperature0–50 °C
Discharge temperature−15–50 °C
Relative humidity5–95 % RH
Installation altitude≤2000 m
Installation formatIntegrated cabinet
CoolingAir cooling
Fire protectionAerosol fire protection

Select the electrical version and equipment package for your destination. The quotation specifies the supplied configuration, documentation and installation scope.

APPLICATION PLANNING

Start with the project load profile.

For commercial premises and industrial facilities, use the site load profile to assess storage for selected-load backup or scheduled energy use. Operating strategy, grid connection and control requirements are designed for the specific project; savings and backup duration are not fixed product guarantees.

Explore this series ↗

Project planning & ordering

How do I select capacity for my facility?

Use the daily load profile, priority equipment and operating schedule. This cabinet has 140.67 kWh nominal energy and 60 kW rated off-grid output. Delivered energy and duration depend on operating limits and losses.

What electrical information is needed for a proposal?

Provide site voltage, phase arrangement, frequency, grid conditions and continuous and startup loads. The specification lists 400/230 V AC and 50/60 Hz; the ordered version and connection design are agreed for the site.

How much grid-side input should be planned?

Maximum grid-side input is 90 kW for load plus charging. Rated off-grid output is 60 kW. Use the input figure when planning site supply and charging, and the output figure when sizing autonomous loads.

What should the project equipment list include?

Identify battery configuration, PCS and BMS versions, EMS functions, cooling, fire protection and connection equipment. Agree optional solar equipment separately and request the final drawings and applicable compliance documents with the proposal.

What space and installation conditions should I plan?

Provide the site layout, access route, foundation conditions, ambient temperature and service clearance. Plan ventilation for the air-cooled IP54 cabinet. Final dimensions and transport weight belong in the approved project drawing and shipping plan.

How can HSY support an OEM/ODM enquiry?

Send the target market, operating requirements, requested branding and quantity. HSY supports OEM/ODM; project scope, delivery, warranty and commercial terms are agreed in the quotation.

Request a UBT-140K-FPA project quotation with your site voltage and frequency, load profile, required operating mode, country and quantity. Include OEM/ODM requirements and the equipment or installation services you want itemized.

Send your product, destination country, quantity and requirements by email or WhatsApp.

These links open your email app or WhatsApp. Your enquiry is sent only when you send it there.

UBT-140K-FPA
IP Geolocation by DB-IP