Energy storage cabinets
Select power, energy and operating modes, and define PCS, BMS and control requirements.
View cabinet solutionStorage cabinets and container-project enquiries for factories, commercial buildings and system integrators. Select around loads, energy needs, grid conditions and the site.

Discuss cabinets and container requirements around project scale and system boundaries.

Select power, energy and operating modes, and define PCS, BMS and control requirements.
View cabinet solution
Discuss project scale, site and system boundaries to prepare an equipment schedule.
Enquire about container projects
Define batteries, power conversion, control, site connections and responsibilities.
Discuss system configurationHSY · HSY-1044K-F
The HSY-1044K-F combines four 261kWh battery cabinets with a 500kVA AC system for commercial and industrial projects requiring coordinated energy, power and control design.
HSY · HSY-100K-F
The HSY-100K-F is a 100kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. Start with a defined 100kWh class: establish site loads, grid conditions and installation space before selecting PCS and controls.
HSY · HSY-120K-F
The HSY-120K-F is a 120kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. The 120kWh class sits between 100kWh and 140kWh. The material shows two 120kWh enclosure arrangements, so include cable access and service clearance in the quotation.
HSY · HSY-140K-F
The HSY-140K-F is a 140kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. Match the 140kWh class to the site energy profile, then compare 120kWh and 160kWh. Review enclosure layout and AC power separately.
HSY · HSY-160K-F
The HSY-160K-F is a 160kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. The 160kWh option increases the energy class beyond 140kWh. When planning more storage, review the enclosure arrangement rather than scaling an earlier specification sheet.
HSY · HSY-180K-F
The HSY-180K-F is a 180kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. The 180kWh option belongs to the larger enclosure group shown in the material. Consider the energy target, equipment arrangement and cooling-air clearances together.
HSY · HSY-200K-F
The HSY-200K-F is a 200kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. Use the 200kWh class to compare battery energy, PCS power and site engineering as separate parts of the procurement scope.
HSY · HSY-221K-F
The HSY-221K-F is a 221kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. Where a specification between 200kWh and 241kWh is needed, the listed 221kWh model offers a distinct selection point rather than rounding the requirement upward.
HSY · HSY-241K-F
The HSY-241K-F is a 241kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. The 241kWh model sits near the upper end of the family and can be compared with 221kWh and 261kWh. Similar energy does not make PCS, protection or site design interchangeable.
HSY · HSY-261K-F
The HSY-261K-F is a 261kWh-class air-cooled LiFePO4 storage cabinet for commercial and industrial projects. 261kWh is the highest class listed in the current capacity chart. For larger projects, compare the separate HSY-1044K-F multi-cabinet system rather than assuming a single-cabinet page defines a parallel system.
HSY · HSY-100K-FPA
A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.
HSY · HSY-120K-FPA
120.57kWh and 50kW rated off-grid output sit between the FPA 100 and 140 models. Compare energy, voltage range and load power rather than treating all 120kWh enclosures as the same machine.
HSY · M3355
M3355 combines 3355kWh rated stored energy with 1.72MW rated AC power for factory, solar and wind-storage projects. Coordinate the battery container, power conversion and distribution around the 550V AC interface, site and operating mode.
Stored energy and AC output are different ratings. Fixed model specifications and configurable project solutions are identified separately.
Select around the actual operating conditions and procurement requirements.
Assess operating strategies and capacity using load profiles and tariff structures.
Define critical loads, supply mode and backup duration before matching power and energy.
Provide grid-connected or off-grid requirements, distribution information and equipment boundaries.
For brands, distributors, installers and integrators: discuss the target market, configuration and procurement plan.
100 kW is rated AC power, while 200 kWh is nominal stored energy. They address load capability and energy needs separately.
200 kWh ÷ 100 kW = 2 h is only the nominal energy-to-power ratio. Actual duration depends on usable energy, losses, temperature, loads and operating strategy.
Provide load profiles, grid-connected or off-grid requirements, site voltage, capacity targets, installation conditions and project location.
List batteries, PCS, BMS, controls, cooling, fire protection, connections and installation responsibilities separately. The quotation defines the agreed scope.
Yes. Provide the target market, product format, quantity and branding or functional requirements to prepare configuration details, documents and a quotation.
Send your application, destination, quantity and power requirements through our enquiry form.