HSY / HAOSHENG
Define the equipment scope for megawatt-scale storage
M3355 1.72MW / 3.355MWh Container Energy Storage System
M3355 combines 3355kWh rated stored energy with 1.72MW rated AC power for factory, solar and wind-storage projects. Coordinate the battery container, power conversion and distribution around the 550V AC interface, site and operating mode.

M3355 container equipment, HSY OEM branding visualization.
This is a megawatt-scale project system. Define delivered equipment, grid interface, protection and fire safety in the project design. Rated energy does not guarantee usable energy or fixed runtime.
Product views and configurations
M3355 combines 3355kWh rated stored energy with 1.72MW rated AC power for factory, solar and wind-storage projects. Coordinate the battery container, power conversion and distribution around the 550V AC interface, site and operating mode.
HSY OEM branding is available. Enclosure, interfaces and delivery markings follow the selected configuration.
M3355 container equipment, HSY OEM branding visualization.
Clear details for product selection
Separate battery and conversion equipment
The specification lists separate battery and power-conversion containers. Define whether the transformer, PCS, distribution, fire protection, installation and commissioning are included in the quotation.
A separate choice from the 1.044MWh multi-cabinet system
This 3.355MWh, 1.72MW container system is separate from HSY-1044K-F. Use the load profile, connection voltage and site conditions to define the solution; nominal energy alone does not guarantee runtime.
Full specifications
| Item | Specification / configuration |
|---|---|
| Model marking | M3355 |
| Rated stored energy | 3355 kWh |
| Rated AC power | 1.72 MW |
| Cells and arrangement | LiFePO4 / 3.2 V / 280 Ah / 9 × 1P416S |
| Battery voltage range | 1040–1518.4 V |
| Rated grid voltage | 550 V |
| Rated grid frequency | 50 Hz |
| Isolation | Transformer isolation |
| Battery container dimensions | 13106 × 2896 × 2438 mm |
| Power-conversion container dimensions | 6058 × 2896 × 2438 mm |
| External communications | Ethernet / Modbus TCP / IEC 104 |
| Cooling | Air cooling |
Units: W / kW = power; Wh / kWh = stored energy; kVA = apparent power and is not interchangeable with kW. V = voltage; A = current; Ah = charge capacity.
This is a megawatt-scale project system. Define delivered equipment, grid interface, protection and fire safety in the project design. Rated energy does not guarantee usable energy or fixed runtime.
Applications
Factory energy management
Develop operating schedules from the load profile and tariff structure.
Solar and wind storage
Size storage against generation, connection and dispatch requirements.
System integration projects
Coordinate the battery, PCS, transformer and site works.
Battery and system safety
System safety brings together battery management, overcurrent protection, isolation, thermal control and the installation environment. Electrical connection, earthing and commissioning require suitably qualified personnel.
Operate within the selected model’s voltage, current and temperature limits. Site protection, fire safety and grid requirements are addressed in the project design.
Certification and export documentation
Include the sales country, installation setting and shipping method in your enquiry. HSY can then coordinate the compliance, test and transport documentation required for the configuration.
Certificates and test documents must cover the actual model and delivered configuration. Project compliance requires the applicable documentation.
Discuss your OEM/ODM project
Importers, distributors and project buyers can discuss branding, packaging, destination-market requirements, connections and system integration. HSY will review configuration, documentation and supply scope for the project.
Share the target configuration, volume and required timing to receive a comparable proposal. Customization feasibility and commercial terms are defined in the quotation.
Configuration options
| Configuration | Battery energy | Configuration detail |
|---|---|---|
| M3355 | 3355 kWh | 1.72 MW AC |
| HSY-1044K-F ↗ | 1044 kWh | 500 kVA AC |
Procurement FAQ
How are containers and equipment scoped in a quotation?
The specification lists separate battery and power-conversion containers. Define whether the transformer, PCS, distribution, fire protection, installation and commissioning are included in the quotation.
Is this another HSY-1044K-F configuration?
This 3.355MWh, 1.72MW container system is separate from HSY-1044K-F. Use the load profile, connection voltage and site conditions to define the solution; nominal energy alone does not guarantee runtime.
How should I match the electrical configuration?
This is a megawatt-scale project system. Define delivered equipment, grid interface, protection and fire safety in the project design. Rated energy does not guarantee usable energy or fixed runtime.
What should I include in an enquiry?
Include country, configuration, quantity, loads and OEM/ODM requirements. For system projects, also provide electrical drawings, site conditions and grid requirements.
Can documentation be matched to my market?
List the required standards, test reports and transport documents. Their scope must match the selected model, configuration and destination.
Tell us about your project
HSY / HAOSHENG
M3355 1.72MW / 3.355MWh Container Energy Storage System
Preparing or copying does not send an enquiry. Review the text before sending it through email or WhatsApp.