Get a quote
EN ⌄
English简体中文Русский

HSY / HAOSHENG

Compare energy and power across cabinet options

HSY-120K-FPA 50kW / 120.57kWh C&I Storage Cabinet

120.57kWh and 50kW rated off-grid output sit between the FPA 100 and 140 models. Compare energy, voltage range and load power rather than treating all 120kWh enclosures as the same machine.

01120.57 kWhNominal battery energy
0250 kWRated off-grid output
03336–432 V DCBattery voltage range
HSY-120K-FPA 50kW / 120.57kWh C&I Storage Cabinet — Equipment exterior

HSY OEM branding visualization; equipment and configuration are agreed with the order.

04LiFePO4Battery chemistry
05Air coolingCooling
06400 / 230 VAC voltage

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

Nominal battery energy120.57 kWh
Rated off-grid output50 kW
Battery voltage range336–432 V DC
Battery chemistryLiFePO4

Clear details for product selection

Compare energy and power across cabinet options

120.57kWh and 50kW rated off-grid output sit between the FPA 100 and 140 models. Compare energy, voltage range and load power rather than treating all 120kWh enclosures as the same machine.

Separate off-grid output from grid input

50kW is rated off-grid output; 75kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.

Full specifications

ItemSpecification / configuration
ModelHSY-120K-FPA
Nominal battery energy120.57 kWh
Rated off-grid output50 kW
Battery voltage range336–432 V DC
CellsLiFePO4 / 3.2 V / 314 Ah
Cell arrangement1P20S × 6
Charge/discharge rate0.4 C
Maximum grid input (load + charging)75 kW
Maximum grid input current108 A
Maximum off-grid output current80 A
AC voltageAC 400 V / 230 V
Wiring3L / N / PE
Frequency50 / 60 Hz
Cabinet size (W × D × H)1000 × 1370 × 2080 mm
CommunicationsEthernet / Wi-Fi / 4G

Units: W / kW = power; Wh / kWh = stored energy; kVA = apparent power and is not interchangeable with kW. V = voltage; A = current; Ah = charge capacity.

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

Applications

Essential commercial loads

Plan backup circuits around rated off-grid output and load-starting requirements.

Solar plus storage

Specify optional MPPT, controls and grid integration for coordinated PV and battery operation.

Site energy management

Develop charge/discharge schedules from the load profile and site conditions.

Battery and system safety

System safety brings together battery management, overcurrent protection, isolation, thermal control and the installation environment. Electrical connection, earthing and commissioning require suitably qualified personnel.

Operate within the selected model’s voltage, current and temperature limits. Site protection, fire safety and grid requirements are addressed in the project design.

Certification and export documentation

Include the sales country, installation setting and shipping method in your enquiry. HSY can then coordinate the compliance, test and transport documentation required for the configuration.

Certificates and test documents must cover the actual model and delivered configuration. Project compliance requires the applicable documentation.

Discuss your OEM/ODM project

Importers, distributors and project buyers can discuss branding, packaging, destination-market requirements, connections and system integration. HSY will review configuration, documentation and supply scope for the project.

Share the target configuration, volume and required timing to receive a comparable proposal. Customization feasibility and commercial terms are defined in the quotation.

Request a quote ↗

Configuration options

ConfigurationBattery energyConfiguration detail
HSY-100K-FPA ↗100.48 kWh40 kW rated off-grid
HSY-120K-FPA120.57 kWh50 kW rated off-grid
HSY-140K-FPA ↗140.67 kWh60 kW rated off-grid

Procurement FAQ

Are F and FPA cabinets of similar capacity the same product?

120.57kWh and 50kW rated off-grid output sit between the FPA 100 and 140 models. Compare energy, voltage range and load power rather than treating all 120kWh enclosures as the same machine.

Is 75kW the continuous output rating?

50kW is rated off-grid output; 75kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.

How should I match the electrical configuration?

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

What should I include in an enquiry?

Include country, configuration, quantity, loads and OEM/ODM requirements. For system projects, also provide electrical drawings, site conditions and grid requirements.

Can documentation be matched to my market?

List the required standards, test reports and transport documents. Their scope must match the selected model, configuration and destination.

Tell us about your project

HSY / HAOSHENG

HSY-120K-FPA 50kW / 120.57kWh C&I Storage Cabinet

Preparing or copying does not send an enquiry. Review the text before sending it through email or WhatsApp.

Send an enquiry with the HSY online form ↗