Get a quote
EN ⌄
English简体中文Русский

HSY / HAOSHENG

Match stored energy to load power

HSY-100K-FPA 40kW / 100.48kWh C&I Storage Cabinet

A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.

01100.48 kWhNominal battery energy
0240 kWRated off-grid output
03280–360 V DCBattery voltage range
HSY-100K-FPA 40kW / 100.48kWh C&I Storage Cabinet — Equipment exterior

HSY OEM branding visualization; equipment and configuration are agreed with the order.

04LiFePO4Battery chemistry
05Air coolingCooling
06400 / 230 VAC voltage

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

Nominal battery energy100.48 kWh
Rated off-grid output40 kW
Battery voltage range280–360 V DC
Battery chemistryLiFePO4

Clear details for product selection

Match stored energy to load power

A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.

Separate off-grid output from grid input

40kW is rated off-grid output; 60kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.

Full specifications

ItemSpecification / configuration
ModelHSY-100K-FPA
Nominal battery energy100.48 kWh
Rated off-grid output40 kW
Battery voltage range280–360 V DC
CellsLiFePO4 / 3.2 V / 314 Ah
Cell arrangement1P20S × 5
Charge/discharge rate0.4 C
Maximum grid input (load + charging)60 kW
Maximum grid input current86 A
Maximum off-grid output current64 A
AC voltageAC 400 V / 230 V
Wiring3L / N / PE
Frequency50 / 60 Hz
Cabinet size (W × D × H)1000 × 1370 × 2080 mm
CommunicationsEthernet / Wi-Fi / 4G

Units: W / kW = power; Wh / kWh = stored energy; kVA = apparent power and is not interchangeable with kW. V = voltage; A = current; Ah = charge capacity.

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

Applications

Essential commercial loads

Plan backup circuits around rated off-grid output and load-starting requirements.

Solar plus storage

Specify optional MPPT, controls and grid integration for coordinated PV and battery operation.

Site energy management

Develop charge/discharge schedules from the load profile and site conditions.

Battery and system safety

System safety brings together battery management, overcurrent protection, isolation, thermal control and the installation environment. Electrical connection, earthing and commissioning require suitably qualified personnel.

Operate within the selected model’s voltage, current and temperature limits. Site protection, fire safety and grid requirements are addressed in the project design.

Certification and export documentation

Include the sales country, installation setting and shipping method in your enquiry. HSY can then coordinate the compliance, test and transport documentation required for the configuration.

Certificates and test documents must cover the actual model and delivered configuration. Project compliance requires the applicable documentation.

Discuss your OEM/ODM project

Importers, distributors and project buyers can discuss branding, packaging, destination-market requirements, connections and system integration. HSY will review configuration, documentation and supply scope for the project.

Share the target configuration, volume and required timing to receive a comparable proposal. Customization feasibility and commercial terms are defined in the quotation.

Request a quote ↗

Configuration options

ConfigurationBattery energyConfiguration detail
HSY-100K-FPA100.48 kWh40 kW rated off-grid
HSY-120K-FPA ↗120.57 kWh50 kW rated off-grid
HSY-140K-FPA ↗140.67 kWh60 kW rated off-grid

Procurement FAQ

Are F and FPA cabinets of similar capacity the same product?

A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.

Is 60kW the continuous output rating?

40kW is rated off-grid output; 60kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.

How should I match the electrical configuration?

This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.

What should I include in an enquiry?

Include country, configuration, quantity, loads and OEM/ODM requirements. For system projects, also provide electrical drawings, site conditions and grid requirements.

Can documentation be matched to my market?

List the required standards, test reports and transport documents. Their scope must match the selected model, configuration and destination.

Tell us about your project

HSY / HAOSHENG

HSY-100K-FPA 40kW / 100.48kWh C&I Storage Cabinet

Preparing or copying does not send an enquiry. Review the text before sending it through email or WhatsApp.

Send an enquiry with the HSY online form ↗

IP Geolocation by DB-IP