HSY / HAOSHENG
Match stored energy to load power
HSY-100K-FPA 40kW / 100.48kWh C&I Storage Cabinet
A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.
HSY OEM branding visualization; equipment and configuration are agreed with the order.
This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.
Product views and configurations
A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.
HSY OEM branding is available. Enclosure, interfaces and delivery markings follow the selected configuration.
Original shared FPA enclosure reference with supplier markings retained. Battery and power ratings follow the model selected on this page. HSY OEM branding is available. Original equipment reference image; original device markings are retained.
Clear details for product selection
Match stored energy to load power
A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.
Separate off-grid output from grid input
40kW is rated off-grid output; 60kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.
Full specifications
| Item | Specification / configuration |
|---|---|
| Model | HSY-100K-FPA |
| Nominal battery energy | 100.48 kWh |
| Rated off-grid output | 40 kW |
| Battery voltage range | 280–360 V DC |
| Cells | LiFePO4 / 3.2 V / 314 Ah |
| Cell arrangement | 1P20S × 5 |
| Charge/discharge rate | 0.4 C |
| Maximum grid input (load + charging) | 60 kW |
| Maximum grid input current | 86 A |
| Maximum off-grid output current | 64 A |
| AC voltage | AC 400 V / 230 V |
| Wiring | 3L / N / PE |
| Frequency | 50 / 60 Hz |
| Cabinet size (W × D × H) | 1000 × 1370 × 2080 mm |
| Communications | Ethernet / Wi-Fi / 4G |
Units: W / kW = power; Wh / kWh = stored energy; kVA = apparent power and is not interchangeable with kW. V = voltage; A = current; Ah = charge capacity.
This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.
Applications
Essential commercial loads
Plan backup circuits around rated off-grid output and load-starting requirements.
Solar plus storage
Specify optional MPPT, controls and grid integration for coordinated PV and battery operation.
Site energy management
Develop charge/discharge schedules from the load profile and site conditions.
Battery and system safety
System safety brings together battery management, overcurrent protection, isolation, thermal control and the installation environment. Electrical connection, earthing and commissioning require suitably qualified personnel.
Operate within the selected model’s voltage, current and temperature limits. Site protection, fire safety and grid requirements are addressed in the project design.
Certification and export documentation
Include the sales country, installation setting and shipping method in your enquiry. HSY can then coordinate the compliance, test and transport documentation required for the configuration.
Certificates and test documents must cover the actual model and delivered configuration. Project compliance requires the applicable documentation.
Discuss your OEM/ODM project
Importers, distributors and project buyers can discuss branding, packaging, destination-market requirements, connections and system integration. HSY will review configuration, documentation and supply scope for the project.
Share the target configuration, volume and required timing to receive a comparable proposal. Customization feasibility and commercial terms are defined in the quotation.
Configuration options
| Configuration | Battery energy | Configuration detail |
|---|---|---|
| HSY-100K-FPA | 100.48 kWh | 40 kW rated off-grid |
| HSY-120K-FPA ↗ | 120.57 kWh | 50 kW rated off-grid |
| HSY-140K-FPA ↗ | 140.67 kWh | 60 kW rated off-grid |
Procurement FAQ
Are F and FPA cabinets of similar capacity the same product?
A 100.48kWh battery paired with 40kW rated off-grid output provides a defined starting point for essential-load planning and storage strategy. It is separate from the capacity-class HSY-100K-F cabinet.
Is 60kW the continuous output rating?
40kW is rated off-grid output; 60kW is maximum combined grid input for loads and charging, not rated output power. PV MPPT and operating strategy are specified for the project.
How should I match the electrical configuration?
This is a specific FPA model, separate from the F capacity-class range. Specify off-grid output, grid input and optional MPPT separately. Grid protection and project compliance require site-specific design.
What should I include in an enquiry?
Include country, configuration, quantity, loads and OEM/ODM requirements. For system projects, also provide electrical drawings, site conditions and grid requirements.
Can documentation be matched to my market?
List the required standards, test reports and transport documents. Their scope must match the selected model, configuration and destination.
Tell us about your project
HSY / HAOSHENG
HSY-100K-FPA 40kW / 100.48kWh C&I Storage Cabinet
Preparing or copying does not send an enquiry. Review the text before sending it through email or WhatsApp.